Artigos Acadêmicos e Noticiosos
URI permanente desta comunidadehttps://repositorio.insper.edu.br/handle/11224/3226
Navegar
1480 resultados
Resultados da Pesquisa
Artigo Científico Biomechanical comparison of three locking plate constructs for stabilization of a femoral segmental defect model in cats(2026) Carbonari, Marcelo José; Coris, Jeniffer Gabriela Figueroa; Rahal, Sheila Canevese; Pereira, César Augusto M.; Cassanego, Guilherme Rech; Wei, Teng Hsiang; Caldeira, Fátima Maria C.This study biomechanically evaluated three titanium locking plate constructs for stabilizing a segmental defect model that simulated a comminuted femoral shaft fracture in cats. Four groups were formed: G1 – single locking plate; G2 – plate-rod construct; G3 – dual plate in an orthogonal configuration; and G4 – intact bone. G1 used 16-hole locking plate with bicortical screws placed in holes 1, 3, 7, 10, 14, and 16. In G2, an intramedullary pin was included, with monocortical screws in the same positions. In G3, screws were placed as in G1, except that monocortical screws were used in holes 7 and 10. Additionally, an 8-hole plate was applied in orthogonal configuration, with monocortical screws placed in holes 1, 3, 6, and 8. All constructs underwent cyclic eccentric axial compression, followed by destructive testing, except G4, which was tested only destructively. During cyclic testing, stiffness did not differ between G2 and G3, while G1 exhibited lower stiffness. Deformation measured with Gauge 1 (16-hole plate) was greatest in G1, with no significant difference between G2 and G3. Deformation measured with Gauge 2 (intramedullary pin and orthogonal plate) was greater in G2 than in G3. In destructive testing, stiffness did not differ between G1 and G2, or between G2 and G3. Maximum force and displacement did not differ among Groups 1, 2 and 3. Group 4 differ from other groups for these variables. In conclusion, both the locking plate–rod construct and the dual titanium locking plate demonstrated similar stiffness, but locking plate–rod configuration exhibited greater deformation.Artigo de Periódico Noticioso 'Cidade de Deus' venceu sem a estatueta do Oscar(2026) França, MichaelArtigo de Periódico Noticioso Projeções de longo prazo do Tesouro mostram deterioração fiscal(2026) Mendes, MarcosArtigo de Periódico Noticioso Consulta da CVM consolida a securitização como eixo do crowdfunding no Brasil(2026) Amaral, Thiago; Marujo, Luiz FelipeArtigo de Periódico Noticioso Ética e Inteligência Artificial: as tensões entre humanidade e tecnologia(2026) Andrade, Caio César Vioto deArtigo de Periódico Noticioso O TCU confisca o direito do empresariado(2025) Sayeg, RicardoArtigo de Periódico Noticioso Patrocinador não é “comprador de espaço”, mas parceiro de construção de valor(2025) Eduardo CorghArtigo de Periódico Noticioso Mudanças no mercado de trabalho(2026) NAERCIO AQUINO MENEZES FILHOArtigo de Periódico Noticioso Decisões do TJ sobre softwares de gestão empresarial colocam transformação digital no banco dos réus(2026) Dib, Adriano; Barbuto, TonyArtigo de Periódico Noticioso A 5G e a pedra lascada: o descompasso entre trabalho e lei(2025) LUCIANA YEUNG LUK TAI
