Desenvolvimento de ferramentas para auxiliar biópsias guiadas por tomografia computadorizada: Angle-Tracker
dc.contributor.advisor | Santos, Raphael Galdino dos | |
dc.contributor.author | Kuwabara, Beatriz Mie Kotsubo | |
dc.contributor.author | Mauad, Fernando Panico | |
dc.contributor.author | Souza, Gabriel Terhorst de | |
dc.contributor.author | Freitas, Luciana Cocito Alves de | |
dc.coverage.cidade | São Paulo | pt_BR |
dc.coverage.pais | Brasil | pt_BR |
dc.creator | Kuwabara, Beatriz Mie Kotsubo | |
dc.creator | Mauad, Fernando Panico | |
dc.creator | Souza, Gabriel Terhorst de | |
dc.creator | Freitas, Luciana Cocito Alves de | |
dc.date.accessioned | 2022-07-02T23:48:47Z | |
dc.date.available | 2022-07-02T23:48:47Z | |
dc.date.issued | 2021 | |
dc.description.abstract | Procedimentos de biópsia guiados por tomografia computadorizada são comuns e essenciais para diagnosticar doenças e elaborar tratamentos adequados ao paciente. Tem-se conhecimento de que, por se tratar de uma operação manual, a taxa de sucesso está intimamente interligada com a experiência e habilidades do médico radiologista. Portanto, visando minimizar as complicações advindas de punções inadequadas ou reposicionamento da agulha, o presente trabalho desenvolverá uma solução que torne mais eficiente o processo de aprendizado de médicos e residentes em radiologia. A solução adotada será capaz de auxiliar na indicação do ângulo e região correta de punção de tal forma que operadores menos experientes sejam capazes de realizar a biópsia sem maiores complicações. A ferramenta NOTION foi utilizada para acompanhar e atualizar o desenvolvimento do projeto entre o grupo, bem como gerenciar o trabalho individual de cada membro. | pt_BR |
dc.description.notes | Projeto realizado no Hospital A.C. Camargo Cancer Center Mentores na Empresa: Dr. Almir Galvão Vieira Bitencourt e Dra. Paula Nicole Vieira Pinto | pt_BR |
dc.description.other | Computed tomography-guided biopsy procedures are common and essential for diagnosing diseases and appropriate preparations for the patient. It is known that, as it is a manual operation, a success rate is closely linked to the experience and skills of the radiologist. Therefore, simplified as complications arising from inadequate punctures or needle repositioning, the present work will develop a solution that makes the learning process of physicians and radiology residents more efficient. The solution adopted will be able to assist in the indication of the correct puncture angle and region in such a way that less experienced operators are able to perform the biopsy without further complications. The NOTION tool was used to monitor and update the development of the project among the group, as well as manage the individual work of each member. | pt_BR |
dc.description.qualificationlevel | Graduação | pt_BR |
dc.format.extent | 51 p. | pt_BR |
dc.format.medium | Digital | pt_BR |
dc.identifier.uri | https://repositorio.insper.edu.br/handle/11224/3708 | |
dc.language.iso | Português | pt_BR |
dc.rights.license | TODOS OS DOCUMENTOS DESTA COLEÇÃO PODEM SER ACESSADOS, MANTENDO-SE OS DIREITOS DOS AUTORES PELA CITAÇÃO DA ORIGEM. | pt_BR |
dc.subject | biópsia | pt_BR |
dc.subject | tomografia-computadorizada | pt_BR |
dc.subject | punções e médico | pt_BR |
dc.subject.keywords | biopsy | pt_BR |
dc.subject.keywords | computed tomography | pt_BR |
dc.subject.keywords | punctures and physician | pt_BR |
dc.title | Desenvolvimento de ferramentas para auxiliar biópsias guiadas por tomografia computadorizada: Angle-Tracker | pt_BR |
dc.type | bachelor thesis | |
dspace.entity.type | Publication | |
local.contributor.boardmember | Szafir, Silvio | pt_BR |
local.contributor.boardmember | Bobrow, Fabio | pt_BR |
local.subject.cnpq | Engenharias | pt_BR |
local.type | Trabalho de Conclusão de Curso | pt_BR |
Arquivos
Pacote original
1 - 1 de 1
- Nome:
- ACCAMARGO_Relatorio_Final_PFE_oficial.pdf
- Tamanho:
- 2.29 MB
- Formato:
- Adobe Portable Document Format
- Descrição:
- Relatório Final PFE - ACCAMARGO
Licença do pacote
1 - 1 de 1
N/D
- Nome:
- license.txt
- Tamanho:
- 282 B
- Formato:
- Item-specific license agreed upon to submission
- Descrição: