Detection of the Optic Nerve Head in Fundus Images of the Retina with Gabor Filters and Phase Portrait Analysis

Unidades Organizacionais

Resumo

We propose a method using Gabor filters and phase portraits to automatically locate the optic nerve head (ONH) in fundus images of the retina. Because the center of the ONH is at or near the focal point of convergence of the retinal vessels, the method includes detection of the vessels using Gabor filters, detection of peaks in the node map obtained via phase portrait analysis, and an intensity-based condition. The method was tested on 40 images from the Digital Retinal Images for Vessel Extraction (DRIVE) database and 81 images from the Structured Analysis of the Retina (STARE) database. An ophthalmologist independently marked the center of the ONH for evaluation of the results. The evaluation of the results includes free-response receiver operating characteristics (FROC) and a measure of distance between the manually marked and detected centers. With the DRIVE database, the centers of the ONH were detected with an average distance of 0.36 mm (18 pixels) to the corresponding centers marked by the ophthalmologist. FROC analysis indicated a sensitivity of 100% at 2.7 false positives per image. With the STARE database, FROC analysis indicated a sensitivity of 88.9% at 4.6 false positives per image.

Palavras-chave

Retinal images; Segmentation; Optic nerve head; Optic disk; Gabor filters; Phase portraits; FROC analysis

Titulo de periódico

Journal of Imaging Informatics in Medicine
DOI

Título de Livro

URL na Scopus

Idioma

Inglês

Notas

Membros da banca

Área do Conhecimento CNPQ

CIENCIAS DA SAUDE

CIENCIAS DA SAUDE::MEDICINA::CLINICA MEDICA::OFTALMOLOGIA

ENGENHARIAS::ENGENHARIA BIOMEDICA

ENGENHARIAS::ENGENHARIA ELETRICA

CIENCIAS EXATAS E DA TERRA::CIENCIA DA COMPUTACAO

CIENCIAS BIOLOGICAS::BIOFISICA

Citação

Avaliação

Revisão

Suplementado Por

Referenciado Por