Gabor filters and phase portraits for the detection of architectural distortion in mammograms

dc.contributor.authorRangayyan, Rangaraj M.
dc.contributor.authorFABIO JOSE AYRES
dc.creatorRangayyan, Rangaraj M.
dc.date.accessioned2024-11-12T00:02:08Z
dc.date.available2024-11-12T00:02:08Z
dc.date.issued2006
dc.description.abstractSegmentation of the tumor in neuroblastoma is complicated by the fact that the mass is almost Always heterogeneous in nature; furthermore, viable Architectural distortion is a subtle abnormality in mammograms, and a source of overlooking errors by radiologists. Computer-aided diagnosis (CAD) techniques can improve the performance of radiologists in detecting masses and calcifications; however, most CAD systems have not been designed to detect architectural distortion. We present a new method to detect and localise architectural distortion by analysing the oriented texture in mammograms. A bank of Gabor filters is used to obtain the orientation field of the given mammogram. The curvilinear structures (CLS) of interest (spicules and fibrous tissue) are separated from confounding structures (pectoral muscle edge, parenchymal tissue edges, breast boundary, and noise). The selected core CLS pixels and the orientation field are filtered and downsampled, to reduce noise and also to reduce the computational effort required by the subsequent methods. The downsampled orientation field is analysed to produce three phase portrait maps: node, saddle, and spiral. The node map is further analysed in order to detect the sites of architectural distortion. The method was tested with 19 mammograms containing architectural distortion. In a preliminary experiment, a sensitivity of 84% was obtained at 7.8 false positives per image.en
dc.formatDigital
dc.format.extentp. 883 – 894
dc.identifier.doi10.1007/s11517-006-0088-3
dc.identifier.issn1741-0444
dc.identifier.issn0140-0118
dc.identifier.urihttps://repositorio.insper.edu.br/handle/11224/7214
dc.language.isoInglês
dc.relation.ispartofMedical & Biological Engineering & Computing (MBEC)
dc.subjectArchitectural distortionen
dc.subjectPhase portraitsen
dc.subjectOriented textureen
dc.subjectGabor filtersen
dc.subjectMammographyen
dc.subjectBreast canceren
dc.subjectComputer-aided diagnosisen
dc.titleGabor filters and phase portraits for the detection of architectural distortion in mammograms
dc.typejournal article
dspace.entity.typePublication
local.identifier.sourceUrihttps://link.springer.com/article/10.1007/s11517-006-0088-3#citeas
local.publisher.countryNão Informado
local.subject.cnpqCIENCIAS DA SAUDE::MEDICINA::RADIOLOGIA MEDICA
local.subject.cnpqCIENCIAS DA SAUDE::MEDICINA::CLINICA MEDICA::CANCEROLOGIA
local.subject.cnpqENGENHARIAS::ENGENHARIA BIOMEDICA
local.subject.cnpqENGENHARIAS::ENGENHARIA ELETRICA
local.subject.cnpqCIENCIAS EXATAS E DA TERRA::MATEMATICA
local.typeArtigo Científico
publicationvolume.volumeNumber44
relation.isAuthorOfPublication37971022-7c69-4e93-9186-4c9431a1f95c
relation.isAuthorOfPublication.latestForDiscovery37971022-7c69-4e93-9186-4c9431a1f95c

Arquivos

Pacote original

Agora exibindo 1 - 2 de 2
Imagem de Miniatura
Nome:
Primeira_Pagina_Artigo_2006_Gabor_filters_and_phase_portraits_for_the_detection_of_architectural_distortion_in_mammograms_TC.pdf
Tamanho:
66.81 KB
Formato:
Adobe Portable Document Format
N/D
Nome:
ACESSO_RESTRITO_Artigo_2006_Gabor_filters_and_phase_portraits_for_the_detection_of_architectural_distortion_in_mammograms_TC.pdf
Tamanho:
551.65 KB
Formato:
Adobe Portable Document Format

Licença do pacote

Agora exibindo 1 - 1 de 1
N/D
Nome:
license.txt
Tamanho:
236 B
Formato:
Item-specific license agreed upon to submission
Descrição: